Key Data Set Information | |
Reference year | 2020 |
Name |
|
Technical purpose of product or process | FURNITURE LINES EMODEL eModel line consists of desks, workbenches, conference tables. EMODEL DESKS Table top types: fixed Table top finish types: Melamine – melamine faced chipboard, thickness 25mm Base types: - T-leg with fixed height – one-segment columns made of steel profiles - T-leg with manual height adjustment – 2-segment columns made of steel profiles - T-leg with electric height adjustment – 3-segment columns made of steel profiles Frame types: - Fixed – steel profiles - Telescopic – steel profiles Foot types: - Foot A – steel profile, plastic caps - Foot B – steel profile with rounded ends Leveling plastic glides or castors with brakes (not applicable to desks with telescopic frame, and desks with manual height adjustment) Finish options: powder coating EMODEL WORKBENCHES Table top types: fixed Table top finish types: Melamine – melamine faced chipboard, thickness 25mm Base types: - H-leg with fixed height – one-segment columns made of steel profiles - H-leg with manual height adjustment – 2-segment columns made of steel profiles - H-leg with electric height adjustment – 3-segment columns made of steel profiles Frame types: - Fixed – steel profiles - Leveling plastic glides Finish options: powder coating FURNITURE LINES EMODEL eModel line consists of desks, workbenches, conference tables. EMODEL CONFERENCE TABLES: Table top types: fixed Table top finish types: Melamine – melamine faced chipboard, thickness 25mm Base types: T-leg with electric height adjustment – 3-segment columns made of steel profiles Frame types: - Fixed – steel profiles - Telescopic – steel profiles Foot types: - Foot A – steel profile, plastic caps - Foot B – steel profile with rounded ends Leveling plastic glides Finish options: powder coating CERTIFICATES Durability certificate for selected configurations APPLICATIONS Office Workstations, Conference and meeting rooms |
General comment on data set | The values determined to calculate the LCA originate from verified Nowy Styl Sp. z o.o. inventory data. The data for the processes come from the following databases: Ecoinvent v.3.5, specific EPDs, ELCD, ÖKOBAUDAT, Ullmann’s, ITB-Data. Specific data quality analysis was a part of external ISO 14001 audit. The allocation rules used for this EPD are based on general ITB PCR A. Production of the desks and tables EASY SPACE, CS5040, EMODEL, PLAY&WORK, LEVITATE is a line process carried out in five factories fo Nowy Styl Sp. z o.o. located in Krosno and Rzepedz (Poland). Allocation was done on product mass basis. All impacts from raw materials extraction are allocated in A1 module of the LCA. 100% of impacts from the line production of Nowy Styl Sp. z o.o. were inventoried and were allocated to the desks and tables production as follows: EASY SPACE, CS5040, EMODEL, PLAY&WORK, LEVITATE. Utilization of packaging material was taken into consideration. Module A2 includes transport of raw materials such as wood-faced boards (MFC), wood, polymers (PA6, PE, POM, PP), steel elements, papers, additives, ancillary materials and packaging materials from their suppliers to Nowy Styl Sp. z o.o. in Krosno and in Rzepedz. Municipal wastes of factory were allocated to module A3. Energy supply was inventoried for whole factory and was allocated to the of the desks and tables EASY SPACE, CS5040, EMODEL, PLAY&WORK, LEVITATE production. Emissions in the factory are measured and were allocated to module A3. The life cycle analysis of the declared products covers “Product Stage”, A1-A3, C2, C3, C4 and D modules (Cradle to Gate with options) accordance with ISO 14040 and ITB PCR A. The details of systems limits are provided in product technical report. All materials and energy consumption inventoried in factories and were included in calculation. In the assessment, all significant parameters from gathered production data are considered, i.e. all material used per formulation, utilized thermal energy, internal fuel and electric power consumption, direct production waste, and all available emission measurements.It can be assumed that the total sum of omitted processes does not exceed 5% of all impact categories. Machines and facilities (capital goods) required for and during productionare excluded, as is transportation of employees. |
Copyright | Yes |
Owner of data set | |
Quantitative reference | |
Reference flow(s) |
|
Time representativeness | |
Data set valid until | 2025 |
Time representativeness description | "08.06.2020" - "08.06.2025" |
Technological representativeness |
Type of data set | EPD | ||||
Subtype | average dataset | ||||
LCA methodology report | |||||
Data sources, treatment and representativeness | |||||
Documentation of data quality management | |||||
Data source(s) used for this data set | |||||
Completeness | |||||
Validation | |||||
| |||||
Compliance Declarations |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Data entry by | |
Time stamp (last saved) | 2022-05-31T09:21:53 |
Data set format(s) | |
Publication and ownership | |
UUID | d164dffb-cd03-4dfa-8f7d-462c76f833c1 |
Date of last revision | 2022-03-18T07:19:18.596631Z |
Data set version | 00.04.001 |
Registration number | 112/2020 |
Owner of data set | |
Copyright | Yes |
License type | Free of charge for all users and uses |
Indicators of life cycle