Instytut Techniki Budowlanej
Data stock: published datasets [ Download ]

Process data set overview page

Data set: Hansen UnitAl curtain walling (00.03.001)

Other versions:00.03.000

Full name
Hansen UnitAl curtain walling
Location
Reference year
2023
Valid until
2028
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Synonyms
Use advice for data set
The life cycle analysis (LCA) of the declared products covers: product stage – modules A1-A3, use stage – modules B4-B6, end of life – modules C3-C4 and benefits and loads beyond the system boundary – module D (cradle-to-gate with options). Energy and water consumption, emissions as well as information on generated wastes were inventoried and were included in the calculations. It can be assumed that the total sum of omitted processes does not exceed 5% of all impact categories. In accordance with EN 15804 + A2, machines and facilities (capital goods) required for the production as well as transportation of employees were not included in LCA.
Data set use approval
General comment
The data selected for LCA analysis originates from ITB-LCI questionnaires completed by HSHansen a/s using the inventory data, ITB and Ecoinvent database v. 3.9. No specific data collected is older than five years and no generic datasets used are older than ten years. The representativeness, completeness, reliability, and consistency are judged as good. Data for Polish electricity was supported by Ecoinvent database v. 3.9 and KOBiZE. KOBiZE data is supplemented with Ecoinvent v. 3.9 data on the national electricity mix impact where no specific indicator data is provided. Specific EPDs were used for hydro aluminium extrusion ingot inputs. Environmental characteristics that were not included in these EPDs were taken from the Ecoinvent. The allocation rules used for this EPD are based on EN 15804 + A2 and ITB-PCR A v 1.6. Production of the curtain wall is a line process conducted in the manufacturing plan located in Glogów Malopolski (Poland). All impacts from raw materials extraction and processing are allocated in A1 module of EPD. Input and output data from the production is inventoried and allocated to the production on the mass basis. Water and energy consumption, associated emissions and generated wastes are allocated to module A3. Energy supply was inventoried for whole production process. Packaging materials were taken into consideration. Minimum 99.0% input materials and 99.9% energy consumption (electricity, gas, LPG, other) were inventoried in a processing plant and were included in the calculation. In the assessment, all significant parameters from gathered production data are considered, i.e. all material used per formulation, utilized thermal energy, and electric power consumption, direct production waste and available emission measurements. Tires consumption for transport was not considered. Substances with a percentage share of less than 0.1% of total mass were excluded from the calculations. The packaging products (wooden pallets) are included.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Independent external review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
HSHansen a/s
Technical purpose
Hansen UnitAl is a unitized curtain wall system for quick closure of the building envelope. It is possible to design the modules with both transparent and infilled areas. The transparent areas can be both fixed glazing and opening vents or a combination of both. It is possible to create interesting facades by adding extra architecture to the exterior of the façade. This could be aluminium cladding, stone cladding etc. The technical specifications of UnitAl curtain wall produced by HSHansen a/s are presented in Table 1 of declaration. More information can be found on the HSHansen a/s website: www.hshansen.com
Input Products
No records found.
Co-Products
No records found.
Data set version
00.03.001
Time stamp (last saved)
2023-09-07T14:00:59
Data set format
Other versions
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)
Tag
Registered in
Process is not registered in any registry
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.